When critical care meets innovation, you get truly intuitive care - you get the Newport e500 Ventilator. With its Intelligent Control™ System for maximum patient/ventilator synchrony, easy-to-use control panel, and a touch screen graphics display monitor; the e500 is the patient-focused ventilator of the future.


Ventilator Specifications
Graphics Display Monitor Specifications
   

New Software Upgrades include new and modified specifications. This page will be updated soon! Contact Us for more details.

 

Designed for simplicity of use, the e500 offers direct access to all ventilation controls along with other frequently used functions such as Inspiratory and Expiratory Hold, 3 min Oxygen, Suction Disconnect and Preset Vent Settings. The logical layout of the front panel and smart alarm systems make ventilator setup and training quick and easy. And the self-calibrating, integrated oxygen monitor with alarms, the panel lock, and an internal battery all provide the smooth ventilator management necessary to assure peace of mind.

Exclusive to the e500 ventilator, the e500 Graphics Display Monitor features a clear view of diagnostic information with touch-screen ease. In addition to 24 hour trend data, the GDM provides an Event History Log that records the 600 most recent occurances of both alarm violations and changes to ventilator settings. The Wave/Loop Freeze with Cursor function allows the user to gather the analysis of time, pressure, volume or flow at any point in the breath.
    


Intelligent Control™ System
FlexCycle™ Flexible Pressure Support Cycling Threshold, Automatic Slope/Rise Adjustment, Automatic Leak Compensation, Dual Control Breath Management (VTPC/VTPS).
Suction Disconnect
Press and hold Alarm Silence for one second to enable. Suspends ventilation while delivering continuous flow after a planned disconnect.
User Set Up Functions
Leak Test, Circuit Compliance Compensation (calculate and enable breathing circuit compliance of flow/volume delivery), enable 90-second Slow Inflation, Altitude Compensation, Language Selection, Violation Message Log.
Bias Flow
Ventilator-set bias flow flushes exhaled CO2 and stabilizes temperature, humidity and baseline pressure in the patient breathing circuit.
Non-invasive Ventilation
Compatible with mask ventilation for continuous or short term use.
O2 Calibration
Automatic oxygen sensor calibration at software determined intervals.
Preset Vent Settings
Mode, Breath type and settings can be preset without affecting current ventilator operation.
   
 